ISO 11890-1:2024

International Standard   Current Edition
· Approved on 08 May 2024 ·

Paints and varnishes — Determination of volatile organic compounds (VOC) and/or semi volatile organic compounds (SVOC) content — Part 1: Gravimetric method for VOC determination

Paints and varnishes
Including coating powders, paint coatings and protective paint systems

ISO 11890-1:2024 Files

English 15 Pages
Current Edition
114.07 USD

ISO 11890-1:2024 Scope

This document is part of the ISO 11890 series, dealing with the sampling and testing of coating materials and their raw materials.

This document is applicable to the determination of volatile organic compound (VOC) content in the following cases:

     case 1: where there are single-pack coating materials other than case 3, and the expected VOC content is greater than a mass fraction of 5 %, including single-pack coating materials cure not through chemical reactions and single-pack coating materials which cannot be measured by ISO 11890-2 due to chemical cure reactions or gas chromatography temperatures leading to formation of new compounds that would not appear under normal cure conditions and impacts VOC/SVOC calculation.;

     case 2: where there are multi-pack coating materials other than case 3 and the expected VOC content is greater than a mass fraction of 1 %;

     case 3: where there are radiation curable coating materials, and the expected VOC content is greater than a mass fraction of 5 %. Radiation curable coating materials in this document include coating materials that are cured by UV, electron beam, and other radiation methods.

If the system of the first case contains SVOC, but do not cure through chemical reactions, the VOC result can be influenced by SVOC, see Annex C. In this case, ISO 11890-2 is preferred. ISO 11890-1 cannot be used for the determination of the SVOC content. In water-borne coating materials, that do not cure through chemical reactions, if the water content is much greater than VOC content and VOC content is less than a mass fraction of 10 %, ISO 11890-2 is preferred.

For all three cases, the main purpose measured is VOC. However, clarify that this VOC content can also contain SVOC. The real VOC content can be lower than the VOC content measured by ISO 11890-1.

The method specified in this document assumes that the volatile matter is either water or organic. However, it is possible that other volatile inorganic compounds are present which can require another suitable method for quantification, which is thus allowed for in the calculations. The method defined in this document is not applicable for determination of water content.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
YSMO GSO 150-2:2020
GSO 150-2:2013 
Yemeni Technical Regulation
Expiration dates for food products - Part 2 : Voluntary expiration dates
GSO 2055-1:2015
 
Gulf Technical Regulation
HALAL FOOD - Part 1 : General Requirements
YSMO GSO 150-1:2020
GSO 150-1:2013 
Yemeni Technical Regulation
Expiration dates for food products -Part 1 : Mandatory expiration dates

Recently Published

ISO 9658:2024
 
International Standard
Steel — Determination of aluminium content — Flame atomic absorption spectrometric method
ISO 23936-4:2024
 
International Standard
Oil and gas industries including lower carbon energy — Non-metallic materials in contact with media related to oil and gas production — Part 4: Fiber-reinforced composite materials
ISO/IEC 8506:2024
 
International Standard
Information technology — Automatic identification and data capture technology — AIDC application in industrial construction
ISO 544:2024
 
International Standard
Welding consumables — Technical delivery conditions for filler materials and fluxes — Type of product, dimensions, tolerances and markings